< Return to Pumps: Additional Info : Trouble Shooting

Trouble Shooting - AT/AP/AP FM
Pump runs erratically (Oscillates) (Machine Guns)
  Possible Cause How to Check Solution
1 Air under-supply.

 

 

 

 

  1. Physically check to make sure that all lines back to the source are at least 3/16 inch I.D. for 5 gallon per minute pumps. ¼ inch I.D. for 10 gallon per minute pumps. 3/8 inch I.D. for 30 gallon per minute pumps.
  2. Multiple or oversized lines are required if multiple air consuming devices are used on the same supply line. Respect all air consumption carts (max. 9.5 SCFM for 5 gpm pumps, 14 SCFM for 10 gpm pumps, and 25 SCFM for 30 gpm pumps).
  3. Check for undersized valves, flow meters and/or regulators supplying the pump. Take into account all devices operating off of the valve(s) and regulator(s). Also note that many valves and regulators give flow capacities sufficient to supply the pump at 60 psi only if the valve or regulator is supplied with 100 psi. (Maximum air pressure past the regulator to the pump is 60 psi!!!)
  4. Minimum operating pressure is 20 psi.
  5.  

  6. Kink in air supply line.
  7. Undersized orifice in tubing connectors.
  8.  

  9. Pump shuttle valve failure.
  10.  

     

  11. Internal pump failure.

 

  1. Install proper tubing size.
  2.  

     

     

     

  3. Install proper air lines for sufficient air consumption at psi requirements.
  4.  

     

     

  5. Install properly sized valves, flow meters and/or regulators. Adjust air supply pressure to the regulator to allow sufficient air flow out of the regulator.
  6.  

     

     

     

  7. Set regulator supplying pump to between 20 and 60 psi.
  8. Replace air supply line.
  9. Replace tubing connectors with those of proper orifice size.
  10. Replace shuttle valve or return pump to White Knight or authorized service center.
  11. Return pump to White Knight or authorized service center.
2 Tubing connector screwed directly into shuttle valve rather than into ell adapter.
  1. Visually inspect for presence of White Knight ell adapter.
  1. Install ell adapter before tubing connector in shuttle valve. If this does not remedy the problem, damage may have occurred to the shuttle valve and shuttle valve replacement may be required.
3 Bad muffler adjustment.
  1. Center pins in adjustable mufflers should be equally adjusted to one turn out from seat for maximum flow or to maximum in without reducing pump flow requirements. In applications where pump is installed more than one meter higher than the tank, adjust the mufflers down to where it just starts to effect the flow at full operation. This will give the best setting to assist with priming without hindering delivery during the run mode. Mufflers must be adjusted equally (though not "fine tuned").
  1. Muffler adjustment can band-aid fix many non pump related problems such as faulty liquid valves down stream. If sensitive or constantly changing muffler adjustment is required, other problems exist. Proceed with other troubleshooting procedures in this section.
4 Air pressure to pump too low.
  1. Inspect settings on regulators and gage levels.
  1. Set air pressure supply to between 20 and 60 psi. In higher lift applications, the pump may need to be set at the higher end to prime.
5 Kink in air supply line(s).
  1. Visually inspect line for kinks.
  1. Replace kinked line(s).
6 Malfunctioning air supply solenoid valve.
  1. Supply pump with air pressure from a source other than that provided by the solenoid valve.
  1. Replace solenoid valve.
7 Plugged Pump Guard inlet filter.
  1. Open Pump Guard filter and visually inspect for obstructions.
  1. Clean out or replace Pump Guard inlet filter.
8 Malfunctioning liquid valve upstream from pump.
  1. Replace inlet tubing with testing tube running directly from inlet on the pump to the tank and see if normal operation resumes.
  1. Replace defective liquid valve.
  Kink in inlet liquid line.
  1. Visually inspect lines for kinks.
  1. Replace kinked line(s).
  Kink in air supply line(s).
  1. Visually inspect line for kinks.
  1. Replace kinked line(s).
9 Outlet air from mufflers (or muffler ports) tied together.
  1. Visually inspect to make sure that muffler exhausts remain independent.
  1. The pump does not need mufflers to run, but pressure from the two ports must remain separate until reaching atmospheric pressure.
10 Ruptured Bellows
  1. Check to see if mist or dripping is coming from mufflers.
  1. Return pump to White Knight or authorized service center.
11 Debris binding up ceramic shuttle valve.
  1. Remove shuttle end pug and ceramic spool will slide right out.
  1. Clean spool and sleeve. Run White Knight on CDA or Nitrogen only.
12 Shuttle Valve Failure.
  1. Replace Shuttle valve and see if normal pump operation resumes.
  1. Replace shuttle valve.
13 Internal pump failure.
  1. Replace pump with compatible White Knight pump and see if normal operation resumes.
  1. Return pump to White Knight or authorized repair station.